To obtain medical device certification in the United States, follow these steps:
Determine Device Classification:
- Class I: Low risk; often exempt from premarket notification.
- Class II: Moderate risk; typically requires premarket notification (510(k)).
- Class III: High risk; requires premarket approval (PMA).
Understand Regulatory Requirements:
- Review FDA guidelines for your specific device type to understand the requirements for registration and certification.
Prepare Documentation:
- For Class I Devices: Register the device and manufacturing facility with the FDA. Most Class I devices are exempt from premarket notification but must still comply with general controls.
- For Class II Devices (510(k) Premarket Notification):
- Prepare a 510(k) submission that includes device description, intended use, substantial equivalence to a predicate device, and performance testing data.
- For Class III Devices (Premarket Approval - PMA):
- Prepare a PMA submission that includes extensive clinical data, detailed device design, manufacturing processes, labeling, and proposed post-market surveillance plans.
- For De Novo Classification:
- Prepare a De Novo submission if the device is novel and does not fit into existing classifications. Provide evidence of safety and effectiveness and a proposed classification.
Implement Quality System Regulations (QSR):
- Develop and maintain a Quality Management System (QMS) that complies with FDA’s QSR (21 CFR Part 820), including design controls, production processes, and documentation.
Register the Device and Facility:
- Complete the device listing and facility registration with the FDA. This step is necessary before you can submit premarket applications.
Submit the Application:
- Submit the appropriate premarket application (510(k), PMA, or De Novo). Follow FDA guidelines for submission formats and requirements.
FDA Review Process:
- 510(k) Review: Typically takes about 90 days. The FDA evaluates the substantial equivalence claim.
- PMA Review: Can take several months to over a year. The review is more extensive, involving clinical data and manufacturing details.
- De Novo Review: Generally takes 6 to 12 months, involving a detailed review to establish a new classification.
Prepare for FDA Inspection:
- The FDA may conduct inspections of your manufacturing facility to ensure compliance with QSR and other regulatory requirements.
Adhere to Post-Market Requirements:
- Report adverse events, maintain compliance with FDA regulations, and prepare for potential follow-up inspections.
Stay Informed and Compliant:
- Keep up-to-date with any changes in FDA regulations and ensure ongoing compliance with all requirements.
Following these steps helps ensure that your medical device meets FDA standards for safety and effectiveness before it is marketed in the U.S.
Contact Us: