What is the detailed process for FDA registration and certification?
Category:行业资讯 Date:2024-08-22 16:49:53 Author: Source:
These steps ensure that medical devices meet FDA standards for safety and effectiveness before they are marketed in the United States.

The detailed process for FDA registration and certification of medical devices involves several key steps, each with specific requirements:7(3).jpg

  1. Determine Device Classification:

    • Class I: Low risk; often exempt from premarket notification but still subject to general controls.
    • Class II: Moderate risk; generally requires premarket notification (510(k)).
    • Class III: High risk; requires premarket approval (PMA).
  2. Establish Regulatory Pathway:

    • 510(k) Premarket Notification: Submit if the device is Class II or if a new Class I device that is not exempt. Demonstrate that the device is substantially equivalent to a legally marketed device.
    • Premarket Approval (PMA): Required for most Class III devices. This process includes extensive clinical data and a rigorous review by the FDA.
    • De Novo Classification: For devices that are novel and do not have a predicate device. This process creates a new classification for the device.
  3. Prepare and Submit Documentation:

    • Device Listing: Register the device with the FDA. This involves providing basic information about the device and the manufacturer. The registration must be updated annually.
    • 510(k) Submission: Prepare and submit a 510(k) application that includes:
      • Device description
      • Intended use
      • Substantial equivalence information
      • Performance data
    • PMA Submission: Submit a PMA application with comprehensive data, including:
      • Clinical trial results
      • Device design
      • Manufacturing processes
      • Labeling and packaging information
  4. Quality System Regulations (QSR):

    • Develop a Quality Management System (QMS) that complies with FDA's QSR (21 CFR Part 820). This includes:
      • Design controls
      • Document controls
      • Production and process controls
      • Corrective and preventive actions
  5. FDA Review:

    • 510(k) Review: The FDA reviews the substantial equivalence claim. The review process typically takes about 90 days. This includes evaluating the device's safety and effectiveness relative to a predicate device.
    • PMA Review: The review process is more comprehensive and includes evaluation of clinical data, manufacturing information, and device performance. This can take several months to over a year.
  6. FDA Inspection:

    • The FDA may conduct inspections of the manufacturing facility to ensure compliance with QSR and other regulatory requirements. This inspection assesses manufacturing practices, record-keeping, and adherence to regulatory standards.
  7. Post-market Requirements:

    • Adverse Event Reporting: Manufacturers must report any adverse events or device-related problems to the FDA. This includes mandatory reporting for serious injuries or deaths.
    • Ongoing Compliance: Ensure continuous adherence to FDA regulations, including periodic inspections, labeling requirements, and reporting changes to the device or manufacturing process.
  8. Device Tracking and Recall (if necessary):

    • Device Tracking: Some devices must be tracked to ensure their safety and effectiveness over time.
    • Recalls: If a device is found to be defective or harmful, the FDA may require a recall to remove the device from the market or correct the issue.

These steps ensure that medical devices meet FDA standards for safety and effectiveness before they are marketed in the United States.

Contact Us:

Whatsapp or Wechat:+86 15816864648;email address:hito.lin@grzan.cn